    Post-mortem — BL08 / GAME-NODE-20 (M1K02)

    Summary

    Node BL08, hosted in chassis M1K02 at DC2SCALE PAR3, experienced a network outage caused by hardware instability following a recent memory upgrade. Service has now been restored.

    Issue 1 — Memory instability (DIMM)

    Following a recent RAM addition, the server's management controller reported a critical DIMM error, which led to a system crash and an unexpected reboot. The most likely cause is a faulty memory module or a compatibility issue with the existing configuration.

    Issue 2 — Network link instability (10G mezzanine)

    After the memory crash, the blade's mezzanine card entered a degraded state. The ixgbe driver reported repeated link_config FAILED -22 errors at boot, and the 10G uplink to the upstream switch kept flapping between up and down, preventing stable connectivity. This behavior is consistent with a NIC left in an inconsistent state following the abrupt crash, and possibly aggravated by the same underlying memory instability.

    Resolution

    A full power cycle of the blade was performed, allowing the mezzanine card to reinitialize properly and the network link to come back up in a stable state. The node is now back online and serving traffic normally.

    Next steps

    An on-site maintenance window will be scheduled at DC2SCALE PAR3 to perform an in-depth diagnostic of the memory modules and replace any faulty DIMM if confirmed. The network interface will also be monitored closely during this period; if instability persists after the memory issue is resolved, the mezzanine card will be replaced as well.

    We apologize for the inconvenience and thank you for your patience.

  • Resolved
    Resolved
    This incident has been resolved.
  • Update
    Update

    The issue stems from a recent RAM upgrade causing instabilities (possibly a faulty RAM module). A thorough on-site test will be performed as soon as possible. We are currently working on bringing the node back online.

  • Identified
    Identified
    We are continuing to work on a fix for this incident.
  • Investigating
    Investigating
    We are currently investigating this incident.

Mar 2026

Mar 2026 to May 2026

Next